Measuring Principle | Radiometric | |
Characteristic / Application | Compact transmitter Non contact measuring technique, for extreme process conditions (temperature, pressure) | |
Interface measurement | Interfaces liquid / liquid also with emulsion layers and interfaces liquid / solid | |
Supply / Communication | AC: 90-253V DC: 18-36V | |
Accuracy | +/-1% | |
Ambient temperature | -40°C...50°C (-40°F...122°F) with cooling jacket: 40°C...120°C (104°F...248°F) | |
Process temperature | Any | |
Process pressure absolute / max. overpressure limit | Any | |
Main wetted parts | Non-contact | |
Process connection | Non-contact | |
Process connection hygienic | Non-contact | |
Sensor length | PVT scintillator 400mm...2000mm >2000mm cascade mode | |
Max. measurement distance | Unlimited measuring range Cascade | |
Output | 4 ... 20 mA HART FOUNDATION Fieldbus PROFIBUS PA | |
Certificates / Approvals | ATEX FM CSA IECExx TIIS NEPSI Gost | |
Options | customer sized source container | |
Specialities | Interface, density and mass flow measurement Calculation and sizing level with Applicator | |
Components | Isotope: Cs137, Co60 Source container: QG020, QG100, QG2000 Display FHX40 Mounting accessories FHG60 |
Measuring Principle | Radiometric | |
Characteristic / Application | Compact transmitter with PT100 input for temperature compensation | |
Supply / Communication | AC: 90-253V DC: 18-36V | |
Ambient temperature | -40°C...50°C / 60°C 40°C...120°C with cooling jacket | |
Process temperature | Any | |
Process pressure absolute | Any | |
Wetted parts | Non-contact | |
Hygienic | Non-contact | |
Sensor length | NaJ scintillator 50x50mm PVT scintillator 200...400mm | |
Output | 4-20mA HART FOUNDATION Fieldbus PROFIBUS PA | |
Certificates / Approvals | ATEX FM CSA IECEx TIIS NEPSI Gost | |
Specialities | Calculation and sizing with Applicator | |
Components | Source: Cs137 Source container: QG020, QG100, QG2000 |
Measuring Principle | Radiometric | |
Characteristic / Application | Compact transmitter | |
Supply / Communication | AC: 90-253V DC: 18-36V | |
Ambient temperature | -40°C ... 50°C / 60°C (-40°F ... 122°F / 140°F) with cooling jacket 40°C ... 120°C (-40°F ... 248°F) | |
Process temperature | Any | |
Process pressure absolute / max. overpressure limit | Any | |
Main wetted parts | Non-contact | |
Process connection hygienic | Non-contact | |
Sensor length | PVT scintillator 200 mm (8") PVT scintillator 400 mm (16") NaJ scintillator 50x50mm (2") | |
Output | 4 ... 20 mA HART FOUNDATION Fieldbus PROFIBUS PA | |
Certificates / Approvals | ATEX FM CSA IECEx TIIS NEPSI Gost | |
Specialities | Interface measurement Calculation and sizing with Applicator | |
Components | Isotope: Cs137, Co60 Source container: QG020, QG100, QG2000 |