| Measuring Principle | Capacitive | |
| Characteristic / Application | Two-rod probe Preconfigured from factory 0%...100% High quality, non-corrosive materials (carbon fibre, stainless steel) Suitable for aggressive liquids (many acids and alkalis) | |
| Supply / Communication | 10 ... 30VDC | |
| Accuracy | < 1% | |
| Ambient temperature | -40 °C ... 70 °C (-40 °F ... 158 °F) | |
| Process temperature | -40 °C ... 100 °C (-40 °F ... 212 °F) | |
| Process pressure absolute / max. overpressure limit | Vacuum ... 10 bar (Vacuum ... 145 psi) | |
| Main wetted parts | Probe rods: 316L/1.4404 / PP Option: carbon fibre PP coated | |
| Process connection | G 1½ NPT 1½ | |
| Sensor length | Total length of probe 2.5 m | |
| Max. measurement distance | 2.5 m (8 ft) | |
| Output | 4 ... 20 mA | |
| Certificates / Approvals | ATEX WHG | |
| Options | Display | |
| Specialities | Probe shorting kit available | |
| Application limits | Changing, non-conductive media, conductivity < 3 0 μS/cm Highly viscous liquids > 2 000 cst | |