FMI21

author:admin Date:2011-4-15 0:19:39Browse number:1740

Technical data

Continuous / Liquids

Measuring PrincipleCapacitive
Characteristic / ApplicationTwo-rod probe
Preconfigured from factory 0%...100%
High quality, non-corrosive materials (carbon fibre, stainless steel)
Suitable for aggressive liquids (many acids and alkalis) 
Supply / Communication10 ... 30VDC
Accuracy< 1%
Ambient temperature-40 °C ... 70 °C
(-40 °F ... 158 °F)
Process temperature-40 °C ... 100 °C
(-40 °F ... 212 °F)
Process pressure absolute / max. overpressure limitVacuum ... 10 bar
(Vacuum ... 145 psi)
Main wetted partsProbe rods:
316L/1.4404 / PP
Option: carbon fibre PP coated
Process connectionG 1½
NPT 1½
Sensor lengthTotal length of probe 2.5 m
Max. measurement distance2.5 m (8 ft)
Output4 ... 20 mA
Certificates / ApprovalsATEX
WHG
OptionsDisplay
SpecialitiesProbe shorting kit available
Application limitsChanging, non-conductive media, conductivity < 3 0 μS/cm
Highly viscous liquids > 2 000 cst