Rosemount 8800D Series Vortex Flowmeter

author:admin Date:2011-4-20 23:34:09Browse number:1649

Rosemount 8800D Series Vortex Flowmeter 

Rosemount Vortex Flowmeters allow you to achieve better measurement practices across your applications by eliminating potential leak points, incorporating gasket-free meter body designs that are immune to vibration, and enabling best installation practices with Reducer™ and MultiVariable™ Vortex.

Reducer™ Vortex can save up to 40% per installation by eliminating the need for field installed reducers.

MultiVariable™ Vortex can save up to 30% per installation by eliminating the need for external temperature compensation for saturated steam applications.

See for yourself how the Rosemount 8800 Vortex Flowmeter can solve your flow challenges.

Features & Benefits

Reduced Engineering, Installation and Commissioning Costs

  • Rosemount sizes vortex meters for every application reducing Engineering Costs.

  • Reducer™ Vortex to eliminate the need for field installed reducers

  • Vortex meters can save up to 40% in installation costs over traditional flowmeter installations.

  • Rosemount Vortex Flowmeters arrive pre-configured, hydrostatically tested, and ready to install.

Increased Plant Availability

  • Avoid costly unscheduled shutdowns due to undetected process changes

  • Rosemount vortex features a non-clog meter body that eliminates the possibility of plugged impulse lines or torn diaphragms on remote seals

  • Able to replace sensor without breaking process seals

Reduced Maintenance Costs

  • Eliminates maintenance costs associated with impulse lines such as clogging and purging

  • No periodic recalibration required

  • One spare sensor works for all meters

Increased Safety and Environmental Compliance

  • Gasket-free meter body reduces potential leakp

  • Use Dual Vortex and FMEDA analysis to simplify SIS compliance

Easier verification and troubleshooting through device diagnostics

  • Internal signal generator standard in every vortex for easy electronics verification

  • Able to easily accept an external source

  • Diagnostics along with help are available for easier troubleshooting

Specifications

Key Specifications
Flowmeter Accuracy± 0.65 % of rate for liquids
± 1% of rate for gas and steam
Turndown38:1
Output 
  • 4-20 mA with HART®
  • 4-20 mA with HART® and Scalable Pulse Output
  • FOUNDATION™ fieldbus with 2 Analog Input blocks, 1 Backup Link Active Scheduler function block, and 1 Integrator function block (1 PID function block optional)
Wetted MaterialStainless Steel - 316 ⁄ 316L and CF3M
Nickel Alloy- C-22 and CW2M
Consult factory for other wetted material options
Flange OptionsANSI Class 150 to 1500
DIN PN 10 to PN 160
JIS 10K to 40K
Flanges are available in a variety of facings
Operating Temperatures-330°F to 800°F (-200°C to 427°C)
Line SizeFlanged - ½-in to 12-in (15 to 300 mm)
Wafer - ½-in to 8-in (15 to 200 mm)
Dual - ½-in to 12-in (15 to 300 mm